Specification :
▪ Data Acquisition Module : Reporting Unit , english or meteric
: Operating power 10-16 VDC
: Power consumption 60 mA Max.
: Serial port 9 pin d-sub connector
: Memory, 128 KB RAM
▪ Operating Temp : Tranducer, -40 to 60 ˚C
▪ Timekeeping : Format: MM/DD and HH:MM
: Accuracy : ± 30 second/month
▪ Barometeric Pressure : Range: 28.25 to 30.75 inches Hg
: Measurement span : 2.50 inches Hg
: Resolution: ±0.01 inch Hg or ± 0.3 hpa
: Altitude offset : 0 to 10.000 feet
: Absolute Accuracy : 0.05 inches Hg
▪ Wind Speed : Range : 0 to 125 mph (0-57 m/s)
: Resolution : >0.1 mph
: Accuracy : ± 1mph
: Starting threshold : 0.8 mph
▪ Wind Direction : Range : 0-360 ˚
: Resolution : >1%
: Accuracy : ± 1 ˚F
▪ Relative Humidity : Range : 0-100% RH
: Accuracy : ± 3% (10-90%)
▪ Air Temperature : -40 to 60 ˚C
▪ Rain Gauge : Max Rate Unlimited
: Tip 0,254mm of rain fall